Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
1.
Ultraschall Med ; 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38484782

RESUMO

As an extension of the clinical examination and as a diagnostic and problem-solving tool, ultrasound has become an established technique for clinicians. A prerequisite for high-quality clinical ultrasound practice is adequate student ultrasound training. In light of the considerable heterogeneity of ultrasound curricula in medical studies worldwide, this review presents basic principles of modern medical student ultrasound education and advocates for the establishment of an ultrasound core curriculum embedded both horizontally and vertically in medical studies.

2.
Diagnostics (Basel) ; 14(6)2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38535014

RESUMO

Ultrasound is used in cardiopulmonary resuscitation (CPR) and advanced life support (ALS). However, there is divergence between the recommendations of many emergency and critical care societies who support its use and the recommendations of many international resuscitation organizations who either recommend against its use or recommend it only in limited circumstances. Ultrasound offers potential benefits of detecting reversable causes of cardiac arrest, allowing specific interventions. However, it also risks interfering with ALS protocols and increasing unhelpful interventions. As with many interventions in ALS, the evidence base for ultrasound use is weak, and well-designed randomized trials are needed. This paper reviews the current theory and evidence for harms and benefits.

3.
Acta Med Port ; 37(1): 42-45, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-37983974

RESUMO

Arterial blood gas, with subsequent radial arterial puncture as a simple access point, comprises a ubiquitous medical procedure in the diagnostic workup of patients admitted to the emergency department with dyspnea. Despite being a relatively safe and technically straightforward procedure, due to its considerable use, it is of vital importance to be able to promptly recognize its potential complications. We present the case of a 96-year-old female patient admitted to the emergency department with dyspnea and cough who underwent left radial arterial puncture for arterial blood gas. A total of three puncture attempts were performed until arterial blood was collected. Roughly two weeks upon observation, the patient was readmitted to the emergency department after the insidious appearance of a painful swelling in the left wrist, with progressive worsening since hospital discharge. On physical examination, a painful erythematous pulsatile swelling in the left wrist's volar aspect was observed, and further point-of-care ultrasound evaluation documented a cysticlike collection, communicating with the radial artery's lumen, and suggesting the probable diagnosis of iatrogenic radial pseudoaneurysm. The patient was hospitalized and underwent surgical resection of radial pseudoaneurysm, with subsequent arterial repair. Although severe complications from arterial blood gas have a low incidence rate, prompt diagnosis and management are required. Therefore, point-of-care ultrasound, as an additional diagnostic tool, may play a role in minimizing the risk of procedural complications.


Assuntos
Falso Aneurisma , Artéria Radial , Feminino , Humanos , Idoso de 80 Anos ou mais , Artéria Radial/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Punções/efeitos adversos , Ultrassonografia , Dor , Dispneia
4.
Endosc Ultrasound ; 12(3): 311-318, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37693111

RESUMO

Simulation has been shown to improve clinical learning outcomes, speed up the learning process, and improve trainee confidence, while taking the pressure off initial face-to-face patient clinical areas. The second part of The World Federation for Ultrasound in Medicine and Biology state-of-the-art paper on the use of simulators provides a general approach on the practical implementation. The importance of needs assessment before developing a simulation-based training program is outlined. We describe the current practical implementation and critically analyze how simulators can be integrated into complex task scenarios to train small or large groups. A wide range of simulation equipment is available especially for those seeking interventional ultrasound training, ranging from animal tissue models, simple synthetic phantoms, to sophisticated high-fidelity simulation platforms using virtual reality. Virtual reality simulators provide feedback and thereby allow trainees to not only to practice their motor skills and hand eye coordination but also to interact with the simulator. Future developments will integrate more elements of automated assessment and artificial intelligence, thereby enabling enhanced realistic training experience and improving skill transfer into clinical practice.

5.
Endosc Ultrasound ; 12(1): 38-49, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36629173

RESUMO

Simulation has been shown to improve clinical learning outcomes, speed up the learning process and improve learner confidence, whilst initially taking pressure off busy clinical lists. The World Federation for Ultrasound in Medicine and Biology (WFUMB) state of the art paper on the use of simulators in ultrasound education introduces ultrasound simulation, its advantages and challenges. It describes different simulator types, including low and high-fidelity simulators, the requirements and technical aspects of simulators, followed by the clinical applications of ultrasound simulation. The paper discusses the role of ultrasound simulation in ultrasound clinical training, referencing established literature. Requirements for successful ultrasound simulation acceptance into educational structures are explored. Despite being in its infancy, ultrasound simulation already offers a wide range of training opportunities and likely holds the key to a broader point of care ultrasound education for medical students, practicing doctors, and other health care professionals. Despite the drawbacks of simulation, there are also many advantages, which are expanding rapidly as the technology evolves.

6.
Med Ultrason ; 25(1): 56-65, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-34762719

RESUMO

The vast majority of clinicians associate diagnostic ultrasound with a tool that is designed for the living patient. However, it is of course possible to apply this imaging technology to evaluate the recently deceased patient for postmortem diagnosis, or even just examine postmortem tissue. We describe several cases in which ultrasound-enabled providers obtain answers in postmortem examinations and discuss potential future strategies and applications. In addition, we will also illustrate the use of sonography in minimally invasive post-mortem tissue sampling (MITS), an approach that can be used in post-mortem minimally invasive autopsies as well as for establishing ultrasound diagnostic parameters in new medical fields such as periodontal and dental implant specialties.


Assuntos
Ultrassonografia , Humanos , Ultrassonografia/métodos , Autopsia/métodos
7.
Diagnostics (Basel) ; 14(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38201360

RESUMO

BACKGROUND: COVID-19 continues to circulate around the world with multiple different strains being active at once. While diagnosis with antigen and molecular testing is more readily available, there is still room for alternative methods of diagnosis, particularly in out-of-hospital settings, e.g., home or nursing homes, and in low-medium income countries, where testing may not be readily available. STUDY OBJECTIVES: To evaluate the performance of two modified corona score methods compared with a traditional corona score approach to identify patients with COVID-19. METHODS: This was a retrospective multicenter study performed to compare the ability to predict SARS-CoV-2 test results on a nasopharyngeal swab between the corona scores and two novel corona scores (modified 1 corona score (M1CS) and modified 2 corona score (M2CS)). The M1CS included lung ultrasound (LUS) and chest X-ray (CXR) results, while the M2SC only utilized LUS findings without CXRs. Emergency physicians performed point-of-care LUS and a physical examination upon admission to the emergency department. RESULTS: Subjects positive for SARS-CoV-2 were older and had higher ferritin levels and temperature and lower diastolic blood pressure and oxygen saturation. The two groups differed on corona score and modified corona scores (p < 0.001 for all). SARS-CoV-2-positive patients had fewer pleural line irregularities (p = 0.025) but presented more frequently with an interstitial pattern on CXRs (p < 0.001). CONCLUSIONS: In our study, LUS alone provided a valuable contribution to the corona score and improved its performance more than when CXR results were included. These results suggest that resource-limited areas where CXRs may be unavailable or prohibitively expensive can utilize an ultrasound as the sole imaging modality without a loss of diagnostic performance for SARS-CoV-2 pneumonia diagnosis.

8.
Ultrasound J ; 14(1): 31, 2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-35895165

RESUMO

OBJECTIVES: The purpose of this study is to provide expert consensus recommendations to establish a global ultrasound curriculum for undergraduate medical students. METHODS: 64 multi-disciplinary ultrasound experts from 16 countries, 50 multi-disciplinary ultrasound consultants, and 21 medical students and residents contributed to these recommendations. A modified Delphi consensus method was used that included a systematic literature search, evaluation of the quality of literature by the GRADE system, and the RAND appropriateness method for panel judgment and consensus decisions. The process included four in-person international discussion sessions and two rounds of online voting. RESULTS: A total of 332 consensus conference statements in four curricular domains were considered: (1) curricular scope (4 statements), (2) curricular rationale (10 statements), (3) curricular characteristics (14 statements), and (4) curricular content (304 statements). Of these 332 statements, 145 were recommended, 126 were strongly recommended, and 61 were not recommended. Important aspects of an undergraduate ultrasound curriculum identified include curricular integration across the basic and clinical sciences and a competency and entrustable professional activity-based model. The curriculum should form the foundation of a life-long continuum of ultrasound education that prepares students for advanced training and patient care. In addition, the curriculum should complement and support the medical school curriculum as a whole with enhanced understanding of anatomy, physiology, pathophysiological processes and clinical practice without displacing other important undergraduate learning. The content of the curriculum should be appropriate for the medical student level of training, evidence and expert opinion based, and include ongoing collaborative research and development to ensure optimum educational value and patient care. CONCLUSIONS: The international consensus conference has provided the first comprehensive document of recommendations for a basic ultrasound curriculum. The document reflects the opinion of a diverse and representative group of international expert ultrasound practitioners, educators, and learners. These recommendations can standardize undergraduate medical student ultrasound education while serving as a basis for additional research in medical education and the application of ultrasound in clinical practice.

9.
World J Exp Med ; 12(2): 16-25, 2022 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-35433318

RESUMO

BACKGROUND: Left ventricular ejection fraction calculation automation typically requires complex algorithms and is dependent of optimal visualization and tracing of endocardial borders. This significantly limits usability in bedside clinical applications, where ultrasound automation is needed most. AIM: To create a simple deep learning (DL) regression-type algorithm to visually estimate left ventricular (LV) ejection fraction (EF) from a public database of actual patient echo examinations and compare results to echocardiography laboratory EF calculations. METHODS: A simple DL architecture previously proven to perform well on ultrasound image analysis, VGG16, was utilized as a base architecture running within a long short term memory algorithm for sequential image (video) analysis. After obtaining permission to use the Stanford EchoNet-Dynamic database, researchers randomly removed approximately 15% of the approximately 10036 echo apical 4-chamber videos for later performance testing. All database echo examinations were read as part of comprehensive echocardiography study performance and were coupled with EF, end systolic and diastolic volumes, key frames and coordinates for LV endocardial tracing in csv file. To better reflect point-of-care ultrasound (POCUS) clinical settings and time pressure, the algorithm was trained on echo video correlated with calculated ejection fraction without incorporating additional volume, measurement and coordinate data. Seventy percent of the original data was used for algorithm training and 15% for validation during training. The previously randomly separated 15% (1263 echo videos) was used for algorithm performance testing after training completion. Given the inherent variability of echo EF measurement and field standards for evaluating algorithm accuracy, mean absolute error (MAE) and root mean square error (RMSE) calculations were made on algorithm EF results compared to Echo Lab calculated EF. Bland-Atlman calculation was also performed. MAE for skilled echocardiographers has been established to range from 4% to 5%. RESULTS: The DL algorithm visually estimated EF had a MAE of 8.08% (95%CI 7.60 to 8.55) suggesting good performance compared to highly skill humans. The RMSE was 11.98 and correlation of 0.348. CONCLUSION: This experimental simplified DL algorithm showed promise and proved reasonably accurate at visually estimating LV EF from short real time echo video clips. Less burdensome than complex DL approaches used for EF calculation, such an approach may be more optimal for POCUS settings once improved upon by future research and development.

10.
Ultrasound Med Biol ; 48(6): 965-974, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35317949

RESUMO

Telemedicine has evolved over the past 50 years, with video consultations and telehealth (TH) mobile apps that are now widely used to support care in the management of chronic conditions, but are infrequently used in acute conditions such as emergencies. In the wake of the COVID-19 pandemic, demand is growing for video consultations as they minimize health provider-patient interactions and thereby the risk of infection. Advanced applications such as tele-ultrasound (TUS) have not yet gained a foothold despite their achieving technical maturity and the availability of software from numerous companies for TUS for their respective portable ultrasound devices. However, ultrasound is indispensable for triage in emergencies and also offers distinct advantages in the diagnosis of COVID-19 pneumonia for certain patient populations such as pregnant women, children and immobilized patients. Additionally, recent work suggests lung ultrasound can accurately risk stratify patients for likely infection when immediate polymerase chain reaction (PCR) testing is not available and has prognostic utility for positive patients with respect to the need for admission and intensive care unit (ICU) treatment. Though currently underutilized, a wider implementation of TUS in TH applications and processes may be an important stepping-stone for telemedicine. The addition of ultrasound to TH may allow it to cross the barrier from being an application used mainly for primary care and chronic conditions to an indispensable tool used in emergency care, disaster situations, remote areas and low-income countries where it is difficult to obtain high-quality diagnostic imaging. The objective of this review was to provide an overview of the current state of telemedicine, insights into current and future use scenarios, its practical application as well as current TUS uses and their potential value with an overview of currently available portable and handheld ultrasound devices. In the wake of the COVID-19 pandemic we point out an unmet need and use case of TUS as a supportive tool for health care providers and organizations in the management of affected patients.


Assuntos
COVID-19 , Telemedicina , Criança , Emergências , Feminino , Humanos , Pandemias , Gravidez , Telemedicina/métodos , Ultrassonografia/métodos
11.
Ultrasound Med Biol ; 48(4): 598-616, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35067423

RESUMO

The use of ultrasound has revolutionized the evaluation of pulmonary complaints and pathology. Historically, most lung ultrasound uses described are limited to B-mode, M-mode and occasionally color Doppler. However, the use of contrast can significantly expand the diagnostic capabilities of lung ultrasound. Ultrasound contrast enables significant expansion of therapeutic and intervention capabilities. We provide a detailed description of contrast administration, phases and uses in lung ultrasound. Additionally provided are example contrast use cases and illustrative examples of contrast use in a wide range of lung ultrasound applications including pneumonia, atelectasis, pulmonary embolism and neoplasms. Clinical practice examples will help providers incorporate contrast use into their lung ultrasound practice.


Assuntos
Meios de Contraste , Pulmão , Pulmão/diagnóstico por imagem , Tórax , Ultrassonografia
12.
J Ultrasound Med ; 41(10): 2547-2556, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35040507

RESUMO

OBJECTIVES: Lung ultrasound (LUS) holds the promise of an accurate, radiation-free, and affordable diagnostic and monitoring tool in coronavirus disease 2019 (COVID-19) pneumonia. We sought to evaluate the usefulness of LUS in the diagnosis of patients with respiratory distress and suspicion of interstitial severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pneumonia, in comparison to other imaging modalities. METHODS: This was a multicenter, retrospective study. LUS was performed, on Emergency Department (ED) arrival of patients presenting for possible COVID-19 evaluation, by trained emergency physicians, before undergoing conventional radiologic examination or while waiting for the report. Scans were performed using longitudinal transducer orientation of the lung regions. CXR was interpreted by radiologists staffing ED radiology. Subjects were divided into two group based on molecular test results. LUS findings were compared to COVID test results, nonlaboratory data, and other imaging for each patient. Categorical variables were expressed as percentages and continuous variables as median ± standard error. RESULTS: A total of 479 patients were enrolled, 87% diagnosed with SARS-CoV-2 by molecular testing. COVID positive and COVID negative patients differed with respect to sex, presence of fever, and white blood cells count. Most common findings on lung point of care ultrasound (POCUS) for COVID-positive patients were B-lines, irregular pleural lines, and small consolidation. Normal chest X-ray was found in 17.89% of cases. CONCLUSIONS: This 479 patient cohort, with COVID-19, found LUS to be noninferior to chest X-ray (CXR) for diagnostic accuracy. In this study, COVID-positive patients are most likely to show B lines and sub-pleural consolidations on LUS examination.


Assuntos
COVID-19 , Pneumonia , COVID-19/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Estudos Retrospectivos , SARS-CoV-2 , Ultrassonografia/métodos
13.
J Ultrasound Med ; 41(8): 2059-2069, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34820867

RESUMO

OBJECTIVES: A paucity of point-of-care ultrasound (POCUS) databases limits machine learning (ML). Assess feasibility of training ML algorithms to visually estimate left ventricular ejection fraction (EF) from a subxiphoid (SX) window using only apical 4-chamber (A4C) images. METHODS: Researchers used a long-short-term-memory algorithm for image analysis. Using the Stanford EchoNet-Dynamic database of 10,036 A4C videos with calculated exact EF, researchers tested 3 ML training permeations. First, training on unaltered Stanford A4C videos, then unaltered and 90° clockwise (CW) rotated videos and finally unaltered, 90° rotated and horizontally flipped videos. As a real-world test, we obtained 615 SX videos from Harbor-UCLA (HUCLA) with EF calculations in 5% ranges. Researchers performed 1000 randomizations of EF point estimation within HUCLA EF ranges to compensate for ML and HUCLA EF mismatch, obtaining a mean value for absolute error (MAE) comparison and performed Bland-Altman analyses. RESULTS: The ML algorithm EF mean MAE was estimated at 23.0, with a range of 22.8-23.3 using unaltered A4C video, mean MAE was 16.7, with a range of 16.5-16.9 using unaltered and 90° CW rotated video, mean MAE was 16.6, with a range of 16.3-16.8 using unaltered, 90° CW rotated and horizontally flipped video training. Bland-Altman showed weakest agreement at 40-45% EF. CONCLUSIONS: Researchers successfully adapted unrelated ultrasound window data to train a POCUS ML algorithm with fair MAE using data manipulation to simulate a different ultrasound examination. This may be important for future POCUS algorithm design to help overcome a paucity of POCUS databases.


Assuntos
Inteligência Artificial , Função Ventricular Esquerda , Algoritmos , Ecocardiografia/métodos , Humanos , Aprendizado de Máquina , Volume Sistólico
15.
Ultrasound Med Biol ; 48(2): 180-187, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34756465

RESUMO

The evolution of ultrasound imaging into a key technology for diagnostic practice has resulted in its incorporation into the education of medical students worldwide. Although the introduction of ultrasound into medical schools' curricula is relatively recent, training of sonographers and other ultrasound users is mature. Ultrasound is being used in a variety of learning environments and clinical settings, from courses in anatomy and physiology to clinical rotations where medical and other students may scan healthy volunteers or patients, sometimes with little to no supervision. Educators may be apprehensive about a perceived high likelihood that students will encounter unexpected findings during these sessions, which could distress the patient or ultrasound model as well as the student, and result in problems that would be more pronounced if such incidental findings are complex. Policies are needed to address how to manage incidental ultrasound findings that are identified during educational activities. This article summarizes the background and provides a framework for establishing and implementing a well-designed and thoughtful approach for dealing with incidental findings observed in volunteer subjects by medical students during training courses in ultrasound diagnostic scanning. Subject confidentiality should be respected, and review of incidental findings should be transparent without provoking unnecessary anxiety. It is the responsibility of the instructor or supervisor to ensure adequate clinical follow-up if indicated.


Assuntos
Educação de Graduação em Medicina , Estudantes de Medicina , Currículo , Humanos , Achados Incidentais , Ultrassonografia
16.
J Ultrasound Med ; 41(4): 855-863, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34133034

RESUMO

OBJECTIVES: To test deep learning (DL) algorithm performance repercussions by introducing novel ultrasound equipment into a clinical setting. METHODS: Researchers introduced prospectively obtained inferior vena cava (IVC) videos from a similar patient population using novel ultrasound equipment to challenge a previously validated DL algorithm (trained on a common point of care ultrasound [POCUS] machine) to assess IVC collapse. Twenty-one new videos were obtained for each novel ultrasound machine. The videos were analyzed for complete collapse by the algorithm and by 2 blinded POCUS experts. Cohen's kappa was calculated for agreement between the 2 POCUS experts and DL algorithm. Previous testing showed substantial agreement between algorithm and experts with Cohen's kappa of 0.78 (95% CI 0.49-1.0) and 0.66 (95% CI 0.31-1.0) on new patient data using, the same ultrasound equipment. RESULTS: Challenged with higher image quality (IQ) POCUS cart ultrasound videos, algorithm performance declined with kappa values of 0.31 (95% CI 0.19-0.81) and 0.39 (95% CI 0.11-0.89), showing fair agreement. Algorithm performance plummeted on a lower IQ, smartphone device with a kappa value of -0.09 (95% CI -0.95 to 0.76) and 0.09 (95% CI -0.65 to 0.82), respectively, showing less agreement than would be expected by chance. Two POCUS experts had near perfect agreement with a kappa value of 0.88 (95% CI 0.64-1.0) regarding IVC collapse. CONCLUSIONS: Performance of this previously validated DL algorithm worsened when faced with ultrasound studies from 2 novel ultrasound machines. Performance was much worse on images from a lower IQ hand-held device than from a superior cart-based device.


Assuntos
Aprendizado Profundo , Algoritmos , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/métodos , Veia Cava Inferior/diagnóstico por imagem
17.
J Ultrasound ; 25(2): 315-318, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32671656

RESUMO

Septic arthritis (SA) is an emergency orthopedic condition that carries significant patient morbidity and mortality. Clinical data and blood test analyses are fairly unreliable in making the diagnosis and, therefore, utilizing a feasible and reliable diagnostic tool is desirable, particularly in emergency settings where rapid diagnosis is pivotal. Here, we report the case of a 58-year-old male presenting to the emergency department with a swollen elbow. After demonstration of a large articular effusion with point-of-care ultrasound, the synovial fluid analysis was compatible with SA. The patient was treated with elbow arthrotomy and systemic antibiotics and discharged shortly thereafter, uneventfully. Finally, we discuss the impact of ultrasound in diagnosing SA and the many advantages that make it the first-line tool in urgent care.


Assuntos
Artrite Infecciosa , Articulação do Cotovelo , Artrite Infecciosa/diagnóstico por imagem , Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/diagnóstico por imagem , Serviço Hospitalar de Emergência , Humanos , Masculino , Pessoa de Meia-Idade , Líquido Sinovial
18.
J Ultrasound Med ; 41(3): 585-595, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33893746

RESUMO

Optic nerve sheath diameter (ONSD) ultrasound is becoming increasingly more popular for estimating raised intracranial pressure (ICP). We performed a systematic review and analysis of the diagnostic accuracy of ONSD when compared to the standard invasive ICP measurement. METHOD: We performed a systematic search of PUBMED and EMBASE for studies including adult patients with suspected elevated ICP and comparing sonographic ONSD measurement to a standard invasive method. Quality of studies was assessed using the QUADAS-2 tool by two independent authors. We used a bivariate model of random effects to summarize pooled sensitivity, specificity, and diagnostic odds ratio (DOR). Heterogeneity was investigated by meta-regression and sub-group analyses. RESULTS: We included 18 prospective studies (16 studies including 619 patients for primary outcome). Only one study was of low quality, and there was no apparent publication bias. Pooled sensitivity was 0.9 [95% confidence intervals (CI): 0.85-0.94], specificity was 0.85 (95% CI: 0.8-0.89), and DOR was 46.7 (95% CI: 26.2-83.2) with partial evidence of heterogeneity. The Area-Under-the-Curve of the summary Receiver-Operator-Curve was 0.93 (95% CI: 0.91-0.95, P < .05). No covariates were significant in the meta-regression. Subgroup analysis of severe traumatic brain injury and parenchymal ICP found no heterogeneity. ICP and ONSD had a correlation coefficient of 0.7 (95% CI: 0.63-0.76, P < .05). CONCLUSION: ONSD is a useful adjunct in ICP evaluation but is currently not a replacement for invasive methods where they are feasible.


Assuntos
Hipertensão Intracraniana , Pressão Intracraniana , Adulto , Humanos , Hipertensão Intracraniana/diagnóstico por imagem , Nervo Óptico/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Ultrassonografia
19.
Ultrasound Med Biol ; 47(11): 3034-3040, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34429231

RESUMO

Chest computed tomography has been frequently used to evaluate patients with potential coronavirus disease 2019 (COVID-19) infection. However, this may be particularly risky for pediatric patients owing to high doses of ionizing radiation. We sought to evaluate COVID-19 imaging options in pediatric patients based on the published literature. We performed an exhaustive literature review focusing on COVID-19 imaging in pediatric patients. We used the search terms "COVID-19," "SARS-CoV2," "coronavirus," "2019-nCoV," "Wuhan virus," "lung ultrasound (LUS)," "sonography," "lung HRCT," "children," "childhood" and "newborn" to query the online databases PubMed, Medical Subject Headings (MeSH), Embase, LitCovid, the World Health Organization COVID-19 database and Medline Bireme. Articles meeting the inclusion criteria were included in the analysis and review. We identified only seven studies using lung ultrasound (LUS) to diagnose severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection in newborns and children. The studies evaluated small numbers of patients, and only 6% had severe or critical illness associated with COVID-19. LUS showed the presence of B-lines in 50% of patients, sub-pleural consolidation in 43.18%, pleural irregularities in 34.09%, coalescent B-lines and white lung in 25%, pleural effusion in 6.82% and thickening of the pleural line in 4.55%. We found 117 studies describing the use of chest X-ray or chest computed tomography in pediatric patients with COVID-19. The proportion of those who were severely or critically ill was similar to that in the LUS study population. Our review indicates that use of LUS should be encouraged in pediatric patients, who are at highest risk of complications from medical ionizing radiation. Increased use of LUS may be of particularly high impact in under-resourced areas, where access to chest computed tomography may be limited.


Assuntos
COVID-19/diagnóstico por imagem , Radiografia/métodos , Ultrassonografia/métodos , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Pulmão/diagnóstico por imagem , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos
20.
Med Ultrason ; 23(1): 70-73, 2021 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-33621275

RESUMO

The analysis of vertical reverberation artefacts is an essential component of the differential diagnosis in pulmonary ultra-sound. Traditionally, they are often, but not exclusively, called B-line artefacts (BLA) and/or comet tail artefacts (CTA), but this view is misleading. In this position paper we clarify the terminology and relation of the two lung reverberation artefacts BLA and CTA to spe-cific clinical scenarios. BLA are defined by a normal pleura line and are a typical hallmark of cardiogenic pulmonary edema after exclusion of certain pathologies including pneumonia or lung contusion, whereas CTAs show an irregular pleura line representing a variety of parenchymal lung diseases. The dual approach using low frequency transducers to determine BLA and high frequency transducer to determine the pleural surface is recommended.


Assuntos
Pneumopatias , Edema Pulmonar , Ultrassonografia , Artefatos , Humanos , Pulmão/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...